network:eapstroubleshooting [2018/01/13 16:31]
tschulz [Jan 13th]
network:eapstroubleshooting [2018/01/15 10:56]
tschulz [Jan 15th]
Line 20: Line 20:
   * **12:25pm** After reducing both links to 1G only one side would get a connection reverted to 10G and rebooted **Elementary_LD** and **Business_AD_RM** ​   * **12:25pm** After reducing both links to 1G only one side would get a connection reverted to 10G and rebooted **Elementary_LD** and **Business_AD_RM** ​
   * **4:30pm** Pulling sftps off the ftp+ module seems to be fixing the issues. ​ But still having issues between **OLD_KSU** to **5th_Floor** planning on fixing moving link to front sftp ports   * **4:30pm** Pulling sftps off the ftp+ module seems to be fixing the issues. ​ But still having issues between **OLD_KSU** to **5th_Floor** planning on fixing moving link to front sftp ports
-  * It's starting to look like we have two bad ftp+ modules in **OLD_KSU** and **Elementary_LD** +  * It's starting to look like we have two bad ftp+ modules in **5th_Floor** and **Elementary_LD** 
 +==== Jan 14th ==== 
 +  * **10am** moved other sftp from ftp+ module to front sftp ports on both **5th_Floor** and **OLD_KSU** ​switches  
 +  * **3pm** still getting about 1 drops/hr on **OLD_KSU** to **Ag_Room** link and 4-6 drops a hr on **Elementary_LD** ​to **Business_AD** all other links are staying up 
 +  * **6pm** it looks like we have a bad ftp+ module in **5th_Floor**,​ **Elementary_LD** and a failing module in **OLD_KSU** or **Ag_Room** 
 +==== Jan 15th ==== 
 +  * **7:30am** moved other sftp from ftp+ module to front sftp ports on both **Ag_Room** and **OLD_KSU** switches  
 +  * **8:30am** link between **Ag_Room** and **Business_AD** started dropping 
 +  * **8:51am** moved back to 10G sftp+ on **OLD_KSU** for **Ag_Room** link 
 +  * **9:00am** moved other sftp from ftp+ module to front sftp ports on both **Ag_Room** and **Business_AD** 
 +  * **11:00am** it looks like only one link is dropping: 1:54 on **Elementary_LD**
 ===== Switch Addresses ===== ===== Switch Addresses =====
 ^Address^Name^ ^Address^Name^
Line 69: Line 78:
 show ports 1:53,1:54 rxerrors show ports 1:53,1:54 rxerrors
 show ports 1:31,2:31 rxerrors show ports 1:31,2:31 rxerrors
 +show switch
 +show version
 </​file>​ </​file>​
  